Technical data:
Switch of press difference for air oil separator component:
a) Operation value: 0.1mpa
b) Voltage (): 24V
c) Current: 0.5A
Switch of press difference for oil filter:
a) Operation value: 0.15 - 0.2mpa
b) Voltage (): 24V
c) Current: 0.5A
Switch of press difference for air filter:
a) Operation value: 6500+500pa
b) Power of signal value: AC220V 0.25A, DC24V 2A
Note:
a) Oil temperature: < 100° C
b) Oil should be cleaned
c) Once the operation is failed, please draw out the valve core to clean